NEW STEP BY STEP MAP FOR DP50RB LOGIN

New Step by Step Map For Dp50rb login

New Step by Step Map For Dp50rb login

Blog Article

Aid 4D probe; identify the probe by means of the ID code; change the 4D generate sign via the  electrical relay to produce the 4D probe perform Typically. 4.2.2 Main board The principle board can be divided into two components: entrance-close of the key board and again-conclusion of the leading board.

The person isn't allowed to open the covers and panel of the technique, neither NOTE: unit disassemble is allowed. To make sure the process efficiency and basic safety, only Mindray engineers or engineers licensed by Mindray can perform upkeep.

Get a complete and extended check out of your anatomical framework via panoramic imaging coupled with velocity indication and forward/backward scan means producing scanning less of a challenge, smoother and even more controllable.

Will not use any cables aside from the cables furnished Together with the unit by Mindray. three. Utilize the cable presented with This method to attach the printer. Other cables might bring about electric shock. Webpage fifteen: Mechanical Safety

Click on Agree and Continue to simply accept cookies and go on to the positioning or click More info to find out comprehensive descriptions of the categories of cookies and pick out regardless of whether to accept sure cookies whilst on the website.

Mindray’s new technology of black & white ultrasound technique, DP-50 Expert, is provided with State-of-the-art imaging technologies permitting further penetration and more rapidly image acquisition with bigger resolution.

S. need to provide the Division with the e mail address if they've a single. The emails provided might be useful for Formal communication with the licensee. However electronic mail addresses are public history. If you do not would like to provide a private deal with, please deliver the Section with an electronic mail address which may be created accessible to the public. Be sure to see our Chapter 455 website page to find out If you're afflicted by this variation.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Evaluating sufferers in currently’s demanding atmosphere needs ground breaking engineering that permits clinicians to help make speedy and assured diagnoses. The versatility from the DP-50 expands your medical utility while assisting to strengthen affected individual treatment.

5.2.3 Geometric positioning precision Longitudinal geometric positioning precision  Exam Step: Do adjustments as the way in testing the most depth. Record the space by 20mm Every phase within the longitudinal targets line using the measurement caliper; Choose the worth with the greatest error (to 20mm), calculate the accuracy using the formula down below The measurement caliper really should be positioned for the higher fringe of the target, Notice:... Site 79 Transverse geometric positioning precision  Take a look at Move: Go over the scan surface area on the phantom with h2o or pair gel, Carefully Get in touch with the probe Along with the scan floor Adjust the depth, building the transverse targets to become exhibited in the graphic. Regulate the main target position to generally be posited beside the transverse targets (the conventional is not apparent) Change parameters like get, TGC, making Each individual transverse targets to generally be Obviously exhibited. Web page eighty 5.five.2.4 Blackout Space Take a look at Step: Include the scan surface with the phantom with h2o or couple gel, Carefully Get in touch with the probe With all the scan surface Change the depth in a decreased price, and established the main focus at the closest destination to the scan surface area. Lessen the worth of parameters like AP, Achieve until the track record sound just might be viewed. Web page 81: Software package Improve And Routine maintenance

Right after prosperous relationship, the newly added network printer title might be shown in the printer driver list. Notice: Just before hook up the community printer, be sure the ultrasound method and the printer are in a similar network area, and the community is Doing work normally. The IP tackle and also the server name need to be legitimate, e.g. Page forty seven DICOM Setting  Enter the AE Title on the ultrasound method, port and PDU in accordance with the precise predicament, and then click [Okay] to exit the screen.

.. Web page 161 The indicator on the printer Errors occur when the adapter turns orange, and also the printing printer adapter operates. Disconnect and join the fails. electrical power adapter, ability within the printer adapter once again, and confirm whether the printing is typical right after 1 moment. Site 163: Electrical Safety Inspection

General performance Take a look at 5.5.1 Check Course of action Resolution Detection depth Geometric Situation Precision Blackout location check Record the exam images 5.5.two Check Material The picture applied Here's just for reference, stay with the graphic influence in the real Observe: circumstance. Specifications: Display screen: established the distinction and brightness within the clinical application value (or even the default status) Procedure atmosphere: dim space, simulating the clinical software setting. Page 76 In problem the transverse resolution screening targets are horizontally exhibited, record the nominal length of two targets that may be Plainly regarded. Repeat the Dp50rb login Procedure earlier mentioned for the transverse resolution tests targets at other depths. As shown in figure beneath. Axial resolution ... Web site 77 When utilizing the convex probe, preserve the transverse resolution tests targets to notice: be displayed near the midline. When utilizing a linear probe with steer functionality, do not turn on the steer function when conduct the transverse resolution examination. Zoom in the location the place the targets Positioned if vital. The diameter of your target stage at a particular depth is equivalent to your transverse resolution in the depth. Web site 78 five.

Immediately after changing the CPU module, important file needs to be generated Yet again according to the new MAC address and published into HDD from the device. Or else, the configuration purpose in the products will likely be dropped. Soon after removing the CPU module, Get rid of panhead screws with washers (twelve M3X6) set on the most crucial device box, you normally takes off the board. Website page 118 Determine eight-29 Disassemble the User interface Assembly (one) Maintain the higher edge of control panel assembly, and open up the control panel. Figure 8-thirty Disassemble the User interface Assembly (2) Immediately after removing a single countersunk head self-tapping screw PT3X10 preset on the control panel and get out the plug on the keyboard and the main device connecting cables, you could possibly take out the control panel assembly.

Take note: Ensure that you could possibly pull out and push to the IO board sockets vertically when pulling out and assembling the IO board assembly within the situation on the take care of. Take away panhead screws with washers M3X6 (4) used to safe the IO board, and afterwards you could consider out the IO board. Web page 116 Remove panhead screws with washers (2 M3X6) which can be fixed on the main unit, just take out the higher baffle then pull out two cables connecting the key board to the facility module assembly.